GainStation 1
9
Again, while the GainStation 1‘s housing is EMV-proof and 
protects against HF-interference, placement of the unit is very 
important since it amplifies microphone signals as well as other 
unwanted signals. Before connecting the GainStation 1 or any 
other equipment turn off all power. 
IMPORTANT: Adjust the voltage setting on the back so that it 
corresponds with the power conditions. 
The following graph shows the correct wiring for connecting 
unbalanced signals to the balanced XLR connectors:
The HI-Z/Line Input connector is designed for unbalanced 
signals only. 
The TRS output connector (see „Analog Outputs“, page 10) can 
be operated both with balanced and unbalanced  wiring. Simply 
use a mono 1/4" plug for unbalanced operation. 
Rear panel/connections
General advices
Output
balanced
unbalanced
1=GND
2 =hot (+)
3 =cold (-)
1
2
3
1
2
3
230 V – 50 Hz/315
 mA
115 V – 60 Hz/630 
mA
VOLTAGE/FUSE