Справочник Пользователя для Lyngdorf Audio TDA 2200

Скачать
Страница из 44
40 
b.  Protection 
Parameter 
Value 
Note 
Grounding 
Mains earth, chassis and audio 
ground are connected 
internally. 
 
Output short circuit current 
±40A 
 
Output DC voltage 
±5V @ <0.1Hz 
 
Over temperature 
All heat sinks and mains-
transformer. 
Auto resetting thermal fuse in 
mains transformer. 
c.  Mains 
Parameter 
Value 
Note 
Mains input connector 
IEC 320 cold type 
Mains lead supplied. 
Mains voltage range 
100-120V AC, 50–60Hz 
115V version 
Mains voltage range 
200-240V AC, 50-60Hz 
230V version 
Internal mains fuse 
8 Amp / 0.25A 
115V version 
Internal mains fuse 
4 Amp / 0.1A 
230V version 
Power consumption 
1.5 W 
STANDBY mode. 
Power consumption 
35 W 
OPERATE mode, no output. 
Power consumption 
116 W 
2*37.5W/4ohms. 
Power consumption 
820 W 
2*300W/4ohms. 
d.  Trigger 
Parameter 
Value 
Note 
TRIGGER OUT connector 
3.5mm (1/8") mono jack 
Case=Gnd, Tip=Input 
TRIGGER OUT Voltage 
12V DC 
Short circuit protected 
 
e.  Mechanical 
Parameter 
Value 
Note 
Width 
450mm (17.72") 
 
Depth 
435mm (13.39") 
Excluding loudspeaker 
connectors (over wheel) 
Depth 
455mm (14.21") 
Including loudspeaker 
connectors (over wheel. 
Height 
88.8mm (3.5") 
Excluding feet. 
Height 
100.6mm (3.96") 
Including feet. 
Net weight 
18.0Kg (37lb.) 
 
Shipping weight 
20.0Kg (41lb.)