- 18 – 
 
 
Figure 9 
Figure 10 
 
Important Note
:  When bridging the CV Series amplifier at one of the distributed voltage outputs, it is 
necessary to connect the Common connections for the distributed voltages together. The commons on 
the secondary side of the output transformers are floating.  This is not true for the low-impedance 
outputs.  Their respective commons are connected internally.
  
 
Power Sequencing 
 
A three pin Euro style terminal and mating connector are supplied with each amplifier to allow 
the amplifier power to be sequenced ON or OFF remotely.  These terminals are located on the 
rear panel of the amplifier.  The three terminals are from left to right, the “Ground, Send and 
Receive.  (See Figure 9) 
 
When used with more than one amplifier the “SEQUENCE” feature will turn ON or OFF the 
amplifiers sequentially at about 0.5 second intervals, preventing a large turn on surge though  
the AC mains supply that could possibly cause disruption of the flow of current through the AC mains. 
 
Note:  Use a remote supply of 12 to 15 VDC.  Maximum current required is 20mA at turn-on, 
drops to ~1mA after amp turns on. 
 
Important NOTE:
  The SEND terminal on the Sequence connector has a +15Vdc potential 
whenever the amplifier is “ON”.  The User should take caution not to short this terminal to 
‘Chassis Ground”.  The +15Vdc supply, internal to the amplifier, could be damaged.
 
 
Turning A Single Amplifier ON / OFF 
 
First, place the CV amplifier’s power switch in the Standby (fully down) position.  Connect the positive side of a 
5to15VDC >20mA supply to the “RCV” terminal of the SEQUENCE connector.  Connect the negative side of the 
supply to the “GROUND” terminal 
of the sequence connector. 
 
As long as the DC voltage is 
present the amplifier will remain on.  
Opening the circuit at the 
“SEQUENCE” connectors 
interrupts the DC voltage, and the 
amplifier will turn off.  If a switch is 
used to control the “SEQUENCE” 
circuit, it should be a SPST (single 
pole single throw) switch, not a 
momentary contact closure.  A 
control device such as a contact 
closure contained within a system 
such as Creston®, AMX® or   
Panja®, as examples, can be used 
to remotely control the Power 
ON/OFF function of the amplifier. 
The contact closure must be a 
latching type and not a momentary 
contact closure. 
 
Sequencing Multiple Amplifiers ON / OFF
 
 
When using multiple amplifiers that utilize the “SEQUENCE” feature of the CV Series amplifiers, connect the 
amplifiers in the following manner.  Starting with the first amplifier in the sequence to be turned on, connect the 
positive side of a 5 to15 VDC >20mA supply to the “RCV” terminal.  Next connect a wire from the “SND” terminal 
of the first amplifier to the “RCV” terminal of the next amplifier to be turned on.  Continue in this manner until all