4. OPERATION
(2) Timing chart
In the following timing chart, operation is performed group-by-group in accordance with the values set
in program No.1.
in program No.1.
Transmission data
Station 0
Servo motor
speed
Servo motor
speed
1)
2)
4)
5)
7)
8)
10)
Station 1
Servo motor
speed
Servo motor
speed
Station 2
Servo motor
speed
Servo motor
speed
Station 3
Servo motor
speed
Servo motor
speed
Station 4
Servo motor
speed
Servo motor
speed
Station 5
Servo motor
speed
Servo motor
speed
Station 6
Servo motor
speed
Station 7
Servo motor
speed
Servo motor
speed
Station 7
Servo motor
speed
Station 8
Servo motor
speed
Station 9
Servo motor
speed
Servo motor
speed
Station 9
Servo motor
speed
Group a
Group b
Group c
Group d
3)
6)
9)
11)
12)
No.
Transmission data
Command
Data No.
1)
Selection of program No.1 of group a
[9] [2]
[6] [0]
2)
Forward rotation start (ST1) ON
[9] [2]
[6] [0]
3)
Forward rotation start (ST1) OFF
[9] [2]
[6] [0]
4)
Selection of program No.1 of group b
[9] [2]
[6] [0]
5)
Forward rotation start (ST1) ON
[9] [2]
[6] [0]
6)
Forward rotation start (ST1) OFF
[9] [2]
[6] [0]
7)
Selection of program No.1 of group c
[9] [2]
[6] [0]
8)
Forward rotation start (ST1) ON
[9] [2]
[6] [0]
9)
Forward rotation start (ST1) OFF
[9] [2]
[6] [0]
10)
Selection of program No.1 of group d
[9] [2]
[6] [0]
11)
Forward rotation start (ST1) ON
[9] [2]
[6] [0]
12)
Forward rotation start (ST1) OFF
[9] [2]
[6] [0]
In addition, parameter values common to the stations of each group can be written and alarm reset
can be made, for example.
can be made, for example.
(3) Group setting instructions
Only one servo amplifier may send a reply in any group. If two or more servo amplifiers send reply
data at the same time, they may become faulty.
data at the same time, they may become faulty.