4. OPERATION
(2) Timing chart
In the following timing chart, operation is performed group-by-group in accordance with the values set
in program No.1.
Transmission data
Station 0
Servo motor 
speed
1)
2)
4)
5)
7)
8)
10)
Station 1
Servo motor 
speed
Station 2
Servo motor 
speed
Station 3
Servo motor 
speed
Station 4
Servo motor 
speed
Station 5
Servo motor 
speed
Station 6
Servo motor 
speed
Station 7
Servo motor 
speed
Station 8
Servo motor 
speed
Station 9
Servo motor 
speed
Group a
Group b
Group c
Group d
3)
6)
9)
11)
12)
No.
Transmission data
Command
Data No.
1)
Selection of program No.1 of group a
[9] [2]
[6] [0]
2)
Forward rotation start (ST1) ON
[9] [2]
[6] [0]
3)
Forward rotation start (ST1) OFF
[9] [2]
[6] [0]
4)
Selection of program No.1 of group b
[9] [2]
[6] [0]
5)
Forward rotation start (ST1) ON
[9] [2]
[6] [0]
6)
Forward rotation start (ST1) OFF
[9] [2]
[6] [0]
7)
Selection of program No.1 of group c
[9] [2]
[6] [0]
8)
Forward rotation start (ST1) ON
[9] [2]
[6] [0]
9)
Forward rotation start (ST1) OFF
[9] [2]
[6] [0]
10)
Selection of program No.1 of group d
[9] [2]
[6] [0]
11)
Forward rotation start (ST1) ON
[9] [2]
[6] [0]
12)
Forward rotation start (ST1) OFF
[9] [2]
[6] [0]
In addition, parameter values common to the stations of each group can be written and alarm reset
can be made, for example.
(3) Group setting instructions
Only one servo amplifier may send a reply in any group. If two or more servo amplifiers send reply
data at the same time, they may become faulty.