15. COMMUNICATION FUNCTIONS
15.12.7 Input devices ON/OFF (test operation)
Each input devices can be turned on/off for test operation. when the device to be switched off exists in the
external input signal, also switch off that input signal.
Send command [9] [2], data No. [0] [0] and data.
Command
Data No.
Set data
[9][2]
[0][0]
See below
b31
b0
0: OFF
1: ON
b1
Command of each bit is transmitted to the slave
station as hexadecimal data.
bit
Signal name
bit
Signal name
bit
Signal name
0 Servo-on (SON)
12 Reverse rotation start (ST2)
24 Temporary stop/restart (STP)
1 Forward rotation stroke limit (LSP)
13
2 Reverse rotation stroke limit (LSN)
14
25
Manual pulse generator
multiplication 1 (TP0)
3 External torque limit selection (TL)
15
4 Internal torque limit selection (TL2)
16 Forced stop (EMG)
26
Manual pulse generator
multiplication 2 (TP1)
5 Proportion control selection (PC)
17 Automatic/manual selection (MD0)
27 Gain switch (CDP)
6 Reset (RES)
18 Proximity dog (DOG)
28
7
19 Program No. selection 1 (DI0)
29 Program input 1  (PI1)
8
20 Program No. selection 2 (DI1)
30 Program input 2  (PI2)
9
21 Program No. selection 3 (DI2)
31 Program input 3  (PI3)
10 Current position latch input (LPS)
22 Program No. selection 4 (DI3)
11 Forward rotation start (ST1)
23 Override selection (OVR)