Basic problem-solving with an amplifier is similar to troubleshooting other electrical or electronic equipment.  Always 
check the most obvious possible causes first, such as the following examples: 
Problem Probable 
Cause Remedy 
No power 
Mains power supply is not fully 
inserted into mains socket 
Mains power supply lead is not fully 
inserted into rear socket 
Plug in securely 
No sound 
Wrong connections between input 
sources and the unit 
Cartridge incorrectly wired 
Check audio input lead connections 
 
Check cartridge wiring 
Sound is not precise, lacking in bass 
and stereo image 
Cartridge incorrectly wired 
 
Input connector plugs not fully 
pushed in 
Output connector plugs not fully 
pushed in 
Double-check cartridge wiring using 
cartridge and turntable 
manuals/wiring diagrams. 
Check plugs are inserted fully and 
securely 
Hum 
Turntable not earthed and needs 
earthing  
 
Turntable already earthed and makes 
hum loop in system   
Audio connector plug not fully 
pushed in 
Cable Fault 
Unsuitable Cable 
(e.g. cable grounds not connected) 
Check turntable earthing lead is 
connected to earthing post on XLPS 
V8 
Disconnect Earthing lead from 
earthing post 
Insert plug securely 
Check cable is connected at both 
ends. 
N.B. some esoteric cables have 
internal wiring intentionally 
disconnected/modified. For best 
results on all inputs AND outputs, 
please use good quality screened 
coax; fully connected signal-to signal, 
screen-to-screen. 
Plop Heard in speakers when 
switching on or off or changing 
MM/MC switch 
High gain of XLPS V8 amplifying 
circuit transients. 
Not a fault. 
 Please ensure volume level on 
amplifier is turned down if switching 
the XLPS V8 on or off or changing 
cartridge type switch whilst 
connected. 