Справочник Пользователя для Emotiva RPA-1

Скачать
Страница из 28
 Page 10
Page 11 
RPA-1 Rear Panel Layout
Serial Number
Record this on page 8 of this user’s guide for reference 
in the event you need service or if the component is 
ever stolen.
RCA Audio Inputs
These RCA inputs provide the signal information for the 
left and right channels of the RPA-1. Simply connect 
them to the appropriate output of the preamplifier or 
other preamp level audio device. 
On Board Fuse
This fuse is a T15AL for 110 volt applications and a T8AL 
for 220 volt applications. Please replace only with the 
correct type of fuse.
Remote Turn On Connector
This 2 wire connection accepts a 5-12 volt input 
for remote activation of the RPA-1. If you have the 
companion Emotiva RSP-1 or are building your own 
cable for a device with a 1/8” jack, be sure to identify 
the polarity of the jack pins. On the Emotiva RSP-1, 
center is positive and outer shield is negative.
Speaker Outputs (5 way Binding Posts)
These are the speaker outputs. The 5 way binding posts 
accept stripped speaker wire, banana plugs (single or 
dual), or spade connectors. Be sure to observe correct 
polarity when connecting speakers and be sure that 
the wires do not touch between positive and negative 
terminals.
Power Receptacle
Standard IEC power receptacle. It is advised that this 
amplifier have a direct connection to a wall outlet. Do 
not plug into a “power strip”.  Line voltage switch above 
selects the appropriate line voltage for your country.
XLR Audio Inputs
These XLR inputs also provide the signal information 
for the left and right channels of the RPA-1 and are the 
preferred method of input signal connection whenever 
possible. Simply connect them to the appropriate 
output of the preamplifier or other preamp level audio 
device that has XLR outputs. 
5
6
7
2
8
9
1
3
4
Turn On Selector Switch
This switch allows you to select how the amplifier will 
turn on and off. 
In the ON (Right) position, the switch on the front of 
the amplifier is the method you will use to power up 
and power down the amplifier. Please note that in 
this configuration, you must manually power up and 
power down the amplifier each time you use it or it 
will have unnecessary standby current draw.
In the SIGNAL (Middle) position, the amplifier 
automatically turns on whenever it senses an audio 
signal on either of the two amplifier channels. The 
circuit stays active for about 30 minutes after the 
absence of any audio signal to account for quiet 
passages of music or dialogue.
In the TRIGGER (Left) position, the amplifier’s ON 
and OFF functions are controlled by a trigger from a 
source or preamplifier device. The trigger accepts 12 
VDC and will turn the amplifier on whenever a trigger 
is present. When there is no trigger, the amplifier goes 
into standby mode. This is the preferred method for 
activating the RPA-1.
Master Power Switch
This rocker switch provides the master power for the 
RPA-1. After it is in the ON position, the amplifier can 
be turned on manually from the front panel switch 
or automatically with the trigger input via 2 wire 
connection.
5
6
7
2
8
9
1
3
4