Справочник Пользователя для Chauvet 360Z-LED

Скачать
Страница из 26
Setup 
 
-6- 
 
Q-Wash 360Z-LED User Manual Rev. 01g 
3. Setup 
   
 
AC Power 
 
The Q-Wash 360Z-LED has an auto-ranging power supply that can work with an input 
voltage range of 100~240 VAC, 50/60 Hz. 
Make sure that you are connecting this product to the proper voltage, as per the 
specifications in this guide, the product’s user manual, or on the product’s sticker. 
 
 
 
 
 
Always connect this product to a protected circuit with an appropriate electrical 
ground to avoid the risk of electrocution or fire. 
 
 
 
   
To determine the power requirements for the Q-Wash 360Z-LED see the label affixed to 
the side of the fixture. Alternatively, you may refer to the Technical Specifications chart in 
the Technical Information chapter of this manual.  
The listed current rating indicates the maximum current draw during normal operation. For 
more information, you may download the “Sizing the Circuit Breakers” document from the 
CHAUVET® Web site. 
 
 
 
 
 
Never connect this product to a rheostat (variable resistor) or dimmer circuit, even if 
the rheostat or dimmer channel serves only as a 0 to 100% switch. 
   
 
AC Plug 
 
The Q-Wash 360Z-LED comes with a power input cord terminated with an IEC connector 
on one end an Edison plug on the other end (US market). If the power input cord that came 
with your product has no plug or you need to change the Edison plug, use the table below 
to wire the new plug. 
 
 
 
   
Connection 
Wire (US) 
Wire (Europe) 
Screw Color (US) 
AC Live 
Black 
Brown 
Yellow or Brass 
AC Neutral 
White 
Blue 
Silver 
AC Ground 
Green/Yellow 
Green/Yellow 
Green 
 
 
 
 
 
Make sure to disconnect the fixture’s power cord before replacing a blown fuse, and 
always replace it with a fuse of the same type and rating. 
   
 
Fuse Replacement 
 
1)   Wedge the tip of a flat head screwdriver into the slot of the fuse holder and pry it out of 
its housing. 
2)  Remove the blown fuse from its holder and replace it with a fuse of the exact same 
type and rating (T 5 A, 250 V).  
2)    Insert the fuse holder back in its place, and reconnect power. 
 
 
 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The fuse is located 
inside this compartment. 
Remove it using a flat 
head screwdriver.