Technical Information 
 
Q-Wash 360Z-LED User Manual Rev. 01g 
 
-19- 
Troubleshooting Guide 
 
 
 
Symptom 
Cause(s) 
Action(s) 
Fixture is on 
LEDs are off 
Fixture defaulted 
Configure fixture’s parameters 
Faulty LED board 
Send unit for repair 
Faulty LED Driver board 
Faulty LED Control board 
Faulty Display board 
Fixture and LEDs are on 
Head fan is off 
Faulty head fan 
Replace head fan 
Faulty sensor or wiring 
Verify temperature sensor and wiring 
Fixture and LEDs are on 
Zoom is inactive 
Faulty wiring  
Verify wiring  
Faulty zoom servo 
Send unit for repair 
Faulty LED Control board 
Faulty Display board 
Pan movement problem 
Faulty sensor 
Replace sensor 
Faulty pan belt 
Replace pan belt 
Faulty pan motor 
Replace pan motor 
Faulty Display board 
Send unit for repair 
Tilt movement problem 
Faulty tilt sensor 
Replace tilt sensor 
Faulty tilt belt 
Replace tilt belt 
Faulty tilt motor 
Replace tilt motor 
Faulty Display board 
Send unit for repair 
Circuit breaker/fuse 
keeps tripping/blowing 
Excessive circuit load 
Reduce total load placed on the electrical circuit 
Short circuit along the power wires 
Check electrical wiring 
Fixture does not power 
up 
No power 
Check for voltage on outlet 
Loose or damaged power cord 
Check power cord 
Blown fuse 
Replace fuse 
Faulty internal power supply 
Send unit for repair 
Fixture does not respond 
to wired DMX or 
responds erratically 
Wrong DMX addressing 
Check unit addressing  
Damaged DMX cables 
Check DMX cables 
Wrong polarity on the controller 
Check polarity switch settings on the controller 
Loose DMX cables 
Check cable connections 
Non DMX cables 
Use only DMX compatible cables 
Bouncing signals 
Install terminator as suggested 
Long cable / low level signal 
Install an optically coupled DMX splitter before a 
long section of cable or right after the fixture with 
the strong signal  
Too many fixtures 
Install an optically coupled DMX splitter after unit 
#32 
Interference from AC wires 
Keep DMX cables separated from power cables 
or fluorescent/black lights 
Faulty Display board 
Send unit for repair 
 
 
 
If you still experience technical problems after trying the above solutions or if you 