Справочник Пользователя для Netgear 2409

Скачать
Страница из 26
Installation Guide for the 9 dBi Omni-directional Antenna ANT2409
2-4
Installing the 9 dBi Omni-directional Antenna
3.
Connect the grounding cable (not included) from the lightning arrestor to the ground of the 
building. 
Grounding cable: The grounding cable must be equivalent or better than: AWG 10, UL 1015, 
Stranded, 600 V, 105 
o
C, green or green/yellow insulation, 2 clip of 5.5 mm inner diameter 
cramped at both ends, cable no longer than 5 meters.   
WARNING: the lightning arrestor and appropriate ground cable must be used for outdoor 
installation. NETGEAR does not assume any responsibility in case of hazard resulting of 
non-compliance with these instructions.  
4.
Screw the N/SMA Reverse Adapter on the lightning arrestor (clockwise) on the second RF 
port. Connect a NETGEAR cable model ACC-10314-01, 02, 03, 04 or 05 (sold separately) to 
the adapter. 
5.
Locate the primary detachable antenna on the wireless access point. Remove the antenna and 
connect the other end of the NETGEAR cable ACC-10314-01, 02, 03, 04 or 05  to this port.
NOTE: On access points with two antennas, if you are only replacing one antenna, be sure to 
replace the primary antenna and do not remove the secondary antenna. 
6.
After attaching your new 9 dBi antenna(s), reconnect your wireless device to the network and 
turn them on.