Справочник Пользователя для 3M C1060

Скачать
Страница из 14
Model C1060 Headset Intercom System 
Replacement Parts and Service 
©3M  2005 November 
 
13 
 
Service Procedures (continued) 
 
Replacing Battery Holder Parts 
 
Tools Required: 
 
1 – Number 0 Phillips Screwdriver 
1 – Soldering iron. 
 
Procedures: 
 
1.  
Make sure power is off and remove Battery. 
2.  Remove two screws and Cover.  (If replacing 
old style Battery Contacts, discard all Battery 
Holder parts, they are not compatible with 
newer Battery Holder parts.) 
3.  Unsolder the two Battery Holder PWA wires. 
4.  Insert the Headband wires through the holes 
from the back side of the replacement Battery 
Holder PWA.  Solder the RED wire to the 
+
 
connection point and the BLACK wire to the 
 connection point. 
 
5.  Press the Battery Latch Spring onto the top 
peg of the Battery Latch.  Insert the Latch with 
Spring down through the top of the Base as 
shown.  The beveled bottom edge of the Latch 
MUST face the battery. 
6.  Press the top of the Spring into the small 
molded ribs located inside the top of the Base. 
7.  Insert the Battery Latch Button through the 
front of BOTH the Base and Latch.  Squeeze 
the parts until they snap securely together. 
8.  Press the Battery Holder PWA onto the pegs 
of the Base noting that one hole is larger than 
the other. 
9.  Place the hole in the Headband over the 
retaining peg in the Cover.  Route the power 
wires between the two posts near the top and 
the three posts near the bottom as shown.  Be 
careful to avoid pinching wires while 
replacing Cover and two screws. 
10.  Install new Headband Pad on Battery Holder 
Cover. 
 
 
 
 
 
Battery Latch 
Button 
Battery Latch 
Battery Latch 
Spring 
Battery Holder PWA 
Power Wire 
Routing