Справочник Пользователя для NorthStar Navigation 961XD

Скачать
Страница из 86
SECTION TWO - Installation
Page 32
961 INSTALLATION MANUAL Revision A
1. Press and hold the PWR key for three seconds, and the 961 will turn 
off.
To turn off an entire system (the two heads and the processor) with two 
control heads that are on:
1. Press and hold the PWR key for approximately two seconds until the 
POWER-OFF dialog appears, as shown.
2. To turn off only one head (where you pressed the PWR key, press the 
THIS HEAD
 key. Otherwise, to turn off the entire system, press the 
BOTH HEADS
 key.
Testing and troubleshooting the 961
To test the system after installation, first apply power to the control head: 
Pressing the control head’s PWR key automatically turns the entire sys-
tem on, including the processor. Next, check for the presence of GPS and 
DGPS signals: For GPS signals, the time-to-first-fix (TTFF) is about two to 
five minutes; for DPGS signals, it may take at least 20 minutes for the first 
channel of the 961’s internal beacon receiver to lock onto a transmit-
ter–keep checking for the presence of the word DGPS in the upper-left 
corner of the CHART screen.
Troubleshooting
common
installation
problems
Typical problems you may encounter during or after the installation pro-
cess are outlined in Tables 2, 3, and 4. If you’ve followed the troubleshoot-
ing steps below and are still experiencing difficulties, call the Northstar 
Service Department at 978-897-6600 and ask to speak with a marine ser-
vice technician.
Table 2:  Troubleshooting the installation  
Problem Area
Symptom
Possible Solutions/Reasons
POWER
Pressing the
 PWR
 button doesn’t power-up 
the unit.
Check the fuse and the power to the 
head.