Справочник Пользователя для Mitsubishi Electronics MR-J2S- CP

Скачать
Страница из 357
 
 
4 -  22 
4. OPERATION 
 
4.3 Manual operation mode 
For machine adjustment, home position matching, etc., jog operation or a manual pulse generator may be 
used to make a motion to any position. 
 
4.3.1 Jog operation 
(1) Setting 
Set the input signal and parameters as follows according to the purpose of use. In this case, the point 
table No. selection 1 to 5 (DI0 to DI4) are invalid. 
Item Setting 
method 
Description 
Manual operation mode selection 
Automatic/manual selection (MD0) 
Open MD0-SG (OFF). 
Servo motor rotation direction 
Parameter No.1 
Refer to (2) of this section. 
Jog speed 
Parameter No.13 
Set the speed of the servo motor. 
Acceleration/deceleration time constant 
Point table No.1 
Use the acceleration/deceleration 
time constants in point table No.1. 
 
(2) Servo motor rotation direction 
Servo motor rotation direction 
Parameter No. 1 setting 
Forward rotation start (ST1) ON 
Reverse rotation start (ST2) ON 
CCW rotation 
CW rotation 
CW rotation 
CCW rotation 
ST1:ON
CCW
CW
ST2:ON
ST2:ON
CCW
CW
ST1:ON
Parameter No. 1
0
Parameter No. 1
1
 
(3) Operation 
By shorting ST1-SG, operation is performed under the conditions of the jog speed set in the parameter 
and the acceleration and deceleration time constants in set point table No.1. For the rotation direction, 
refer to (2) of this section. By shorting ST2-SG, the servo motor rotates in the reverse direction to 
forward rotation start (ST1).