(1) Concept of electronic gear 
Use the electronic gear (parameters No.4, 5) to make adjustment so that the servo amplifier setting 
matches the moving distance of the machine. Also, by changing the electronic gear value, the machine 
can be moved at any multiplication ratio to the moving distance on the servo amplifier. 
Parameter No. 4
Parameter No. 5
CMX
CDV
 
Electronic gear
Parameters No. 4, 5
Encoder feedback pulses
CMX
CDV
Deviation 
counter
Motor
Encoder
M
ov
ing 
d
is
tanc
e
+
-
 
 
The following examples are used to explain how to calculate the electronic gear value. 
POINT 
 
The following specification symbols are needed for electronic gear 
calculation. 
Pb  : Ballscrew lead [mm(in.)] 
n  
: Reduction ratio 
Pt  : Servo motor resolution [pulse/rev] 
S  : Travel per servo motor revolution [mm/rev] 
 
(a) Ballscrew setting example 
Machine specifications 
 
Ballscrew lead: Pb   10 (0.39) [mm(in.)] 
Reduction ratio: n   1/2 
Servo motor resolution: Pt   131072 [pulse/rev] 
Servo motor 131072[pulse/rev]
n
NM
NL
Pb=10(0.39)[mm(in.)]
n=NL/NM=1/2
 
CMX
CDV
S
p
t
5000
131072
1250
32768
p
t
n          1000
 p
b
131072
1/2   10   1000
 
Hence, set 32768 to CMX and 1250 to CDV. 
 
(b) Conveyor setting example 
Machine specifications 
 
Pulley diameter: r   160 (6.30) [mm(in.)] 
Reduction ratio: n   1/3 
Servo motor resolution: Pt   131072 [pulse/rev] 
Servo motor
131072[pulse/rev]
r=160(6.30)[mm(in.)]
n
NM
NL
n=NL/NM=1/3
 
CMX
CDV
p
t
S
32768
41888
167551.61
131072
p
t
n   r        1000
131072
1/3   160        1000
 
Reduce CMX and CDV to the setting range or less, and round off the first decimal place. 