6 -  5 
6. MR Configurator (SERVO CONFIGURATION SOFTWARE) 
 
(3) Parameter value batch-read ( c) ) 
Click the “Read All” button to read and display all parameter values from the servo amplifier. 
 
(4) Parameter value batch-write ( d) ) 
Click the “Write All” button to write all parameter values to the servo amplifier. 
 
(5) Parameter change list display ( e) ) 
Click the “Change List” button to show the numbers, names, initial values and current values of the 
parameters whose initial value and current value are different. In the offline mode, the parameter 
change list is not shown. 
 
(6) Parameter detail information ( f) ) 
Click the “Help” button or double-click the display field to show the detailed explanation of each 
parameter. 
 
(7) Parameter default value indication ( g) ) 
Click the “Set to default” button to show the initial value of each parameter. 
 
(8) Parameter value change ( h) ) 
Choose the parameter to be changed, enter a new value into the “Parameter value” input field, and 
press the enter key or Enter Data button. 
 
(9) Parameter data file read 
Used to read and display the parameter values stored in the file. Use the file selection window to read. 
 
(10) Parameter value storage 
Used to store all parameter values being displayed on the window into the specified file. Use the file 
selection window to store. 
 
(11) Parameter data list print 
Used to print all parameter values being displayed on the window. Use the “File” menu on the menu 
bar to print. 
 
(12) Parameter list window closing ( i) ) 
Click the “Close” button to close the window. If the “Close” button is clicked without (1) parameter 
value write or (4) parameter value batch-write being performed, the parameter value changed is 