11 -  9 
11. TROUBLESHOOTING 
 
11.2.3 Remedies for warnings 
CAUTION 
If an absolute position counter warning (AL.E3) occurred, always make home 
position setting again. Otherwise, misoperation may occur. 
 
POINT 
 
When any of the following alarms has occurred, do not resume operation by 
switching power of the servo amplifier OFF/ON repeatedly. The servo 
amplifier and servo motor may become faulty. If the power of the servo 
amplifier is switched OFF/ON during the alarms, allow more than 30 
minutes for cooling before resuming operation. 
Excessive regenerative warning (AL.E0) 
Overload warning 1 (AL.E1) 
 
If AL.E6 occurs, the servo off status is established. If any other warning occurs, operation can be 
continued but an alarm may take place or proper operation may not be performed. Use the optional MR 
Configurator (servo configuration software) to refer to the cause of warning. 
Display Name 
Definition 
Cause 
Action 
Positioning operation 
was performed 
without home 
position return. 
1. Positioning operation was performed 
without home position return. 
Perform home position return. 
In incre
m
ental syste
m
 
Home position return 
ended abnormally. 
2. Home position return speed could not be 
decreased to creep speed. 
3. Limit switch was actuated during home 
position return starting at other than 
position beyond dog. 
Review home position return 
speed/creep speed/moving 
distance after proximity dog. 
Positioning operation 
was performed 
without home 
position setting. 
1. Positioning operation was performed 
without home position setting. 
Perform home position setting. 
Home position setting 
ended abnormally. 
2. Home position setting speed could not be 
decreased to creep speed. 
3. Limit switch was actuated during home 
position setting starting at other than 
position beyond dog. 
Review home position setting 
speed/creep speed/moving 
distance after proximity dog. 
4. Voltage drop in encoder 
(Battery disconnected.) 
After leaving the alarm 
occurring for a few minutes, 
switch power off, then on again. 
Always make home position 
setting again. 
5. Battery voltage low 
AL.90 Home 
position 
return  
incomplete 
In
 a
bs
ol
ut
e p
os
it
ion
 det
ect
io
n s
ys
tem 
Operation was 
performed without 
making home position 
setting while an 
absolute position 
erase (AL.25) is being 
occurred. 
6. Battery cable or battery is faulty. 
Change battery. Always make 
home position setting again. 
1. Battery cable is open. 
Repair cable or changed. 
AL.92 Open 
battery 
cable warning 
Absolute position 
detection system battery 
voltage is low. 
2. Battery voltage supplied from the servo 
amplifier to the encoder fell to about 
3.2V or less. 
(Detected with the encoder) 
Change battery. 
1. Droop pulses remaining are greater 
than the in-position range setting. 
Remove the cause of droop pulse 
occurrence 
2. Command pulse entered after clearing 
of droop pulses. 
Do not enter command pulse 
after clearing of droop pulses. 
AL.96 Home 
position 
setting warning 
Home position setting 
could not be made. 
3. Creep speed high. 
Reduce creep speed.