Справочник Пользователя для Mitsubishi Electronics MR-J2S- CP

Скачать
Страница из 357
 
 
14 -  26 
14. OPTIONS AND AUXILIARY EQUIPMENT 
 
14.1.5 Junction terminal block (MR-TB20) 
POINT 
 
When using the junction terminal block, you cannot use SG of CN1A-20 
and CN1B-20. Use SG of CN1A-4 and CN1B-4. 
 
(1) How to use the junction terminal block 
Always use the junction terminal block (MR-TB20) with the junction terminal block cable (MR-J2TBL 
 M) as a set. A connection example is shown below. 
Servo amplifier
Junction terminal block
MR-TB20
CN1A
or
CN1B
Cable clamp
(AERSBAN-    ESET)
Junction terminal
block cable
(MR-J2TBL    M)
 
Ground the junction terminal block cable on the junction terminal block side with the standard 
accessory cable clamp fitting (AERSBAN- ESET). For the use of the cable clamp fitting, refer to 
section 13.2.6, (2)(c). 
 
(2) Terminal labels 
The junction terminal block does not include the terminal block labels which indicate the signal 
layouts for MR-J2S-CP. Cut off the terminal block label in Appendix 2 at the dotted line and fold it up 
at the centerline for use. 
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
1) For CN1A
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
2) For CN1B
PP
LG
OPC
COM
PG
P15R
NP
NG
SG
DOG
SD
ZP
CPO
VC
MEND
SG
ST1
TLA
VDD
LG
DIO
ST2
MD0
P15R
DI1 LSP
COM SON
ALM SD
LSN RD
 
(3) Outline drawing 
[Unit: mm]
([Unit: in.])
6
0(
2
.3
6)
7
5
0(
1
.9
7)
117(4.61)
126(4.96)
(0
.2
8)
MITSUBISHI
MR-TB20
46
.2
(1.
82)
Terminal screw: M3.5
Applicable cable: Max. 2mm
(Crimping terminal width: 7.2mm (0.283 in) max.)
2
2-   4.5(0.18)
B1
B10
A1
A10
15
10 11 12
14
13
4
0
1
2
3
5
6
7
8
9
16 17 18 19
Terminal