Справочник Пользователя для Mitsubishi Electronics MR-J2S- CP

Скачать
Страница из 357
 
 
3 -  14 
3. SIGNALS AND WIRING 
 
3.4.2 Movement finish Rough match In position 
POINT 
 
If an alarm cause, etc. are removed and servo-on occurs after a stop is 
made by servo-off, alarm occurrence or Forced stop (EMG) ON during 
automatic operation, Movement finish (MEND), Rough-match, (CPO) and 
In position (INP) are turned on. To resume operation, confirm the current 
position and the selected point table No. for preventing unexpected 
operation. 
 
(1) Movement finish 
The following timing charts show the output timing relationships between the position command 
generated in the servo amplifier and the movement finished (MEND). This timing can be changed 
using parameter No. 6 (in-position range). MEND-SG are connected in the servo-on status. 
Forward rotation start (ST1)
or reverse rotation start (ST2)
Position command and 
servo motor speed
3ms or less
In-position range
Servo motor speed
Position command
OFF
ON
OFF
ON
Movement finish (MEND)
 
When parameter No. 6 is small 
 
Forward rotation start (ST1)
or reverse rotation start (ST2)
Position command and 
servo motor speed
Movement finish (MEND)
3ms or less
In-position range
Servo motor speed
Position command
OFF
ON
OFF
ON
 
When parameter No. 6 is large 
 
(2) Rough match 
The following timing charts show the relationships between the signal and the position command 
generated in the servo amplifier. This timing can be changed using parameter No. 12 (rough match 
output range). CPO-SG are connected in the servo-on status. 
 
ON
OFF
ON
OFF
Position command
Rough match (CPO)
3ms or less
Forward rotation start 
(ST1) or
 reverse rotation start 
(ST2)
 
ON
OFF
ON
OFF
Position command
Rough match (CPO)
3ms or less
Rough match output range
Forward rotation start
(ST1) or 
reverse rotation start
(ST2)
 
When "0" is set in parameter No. 12 
When more than "0" is set in parameter No. 12