Справочник Пользователя для Mitsubishi Electronics MR-J2S- CP

Скачать
Страница из 357
 
 
3 -  22 
3. SIGNALS AND WIRING 
 
(b) Lamp load 
For use of internal power supply 
For use of external power supply 
Servo amplifier
COM
R
VDD
24VDC
SG
ALM, etc
 
(Note)
24VDC
  10%
Servo amplifier
COM
R
VDD
24VDC
SG
ALM, etc
Do not connect
VDD-COM.
 
Note. If the voltage drop (maximum of 2.6V) interferes with the 
relay operation, apply high voltage (up to 26.4V) from 
external source. 
 
 
(3) Encoder pulse output DO-2 
(a) Open collector system 
Interface 
Servo amplifier
OP
5 to 24VDC
Photocoupler
SD
Max. output current : 35mA
LG
Servo amplifier
OP
SD
LG
 
(b) Differential line driver system 
1) Interface 
Max. output current: 35mA 
LA
(LB, LZ)
LAR
(LBR, LZR)
LG
SD
LA
(LB, LZ)
LAR
(LBR, LZR)
SD
Servo amplifier
Servo amplifier
Am26LS32 or equivalent
High-speed photocoupler
150
100