Справочник Пользователя для Mitsubishi Electronics MR-J2-03A5

Скачать
Страница из 185
3 -  37
3. SIGNALS AND WIRING
(3) Pulse train input interface DI-2
Provide a pulse train signal in the open collector or differential line driver system.
(a) Open collector system
1) Interface
Servo amplifier
P24L
Max. input pulse
frequency 200kpps
Approx. 1.2k
Ω
PP(NP)
Approx. 10mA
SG
SD
VDD
OPC
P24G
24VDC
2) Conditions of the input pulse
0.9
0.1
tc
tHL
tc
tLH
tF
tLH = tHL 
<
 0.2
µ
s
tc 
2
µ
s
tF 
3
µ
s
PP
NP