3 -  49 
3. CC-LINK COMMUNICATION FUNCTIONS 
 
3.7.5 Writing the data 
This section explains the programs for writing various data to the servo amplifier. 
 
(1) Writing the servo motor speed data of point table 
Change the servo motor speed data in the point table No.1 of the servo amplifier of station 2 to "100". 
The following shows a program example for writing data to the servo amplifier when two stations are 
occupied. Writing is disabled for the servo amplifier when one station is occupied. 
 
Code No. 
Description 
H8D01 
Write of servo motor speed data of point table No.1 
(hexadecimal) 
 
Set data 
Description 
K100 
Servo motor speed data of point table No.1 
(decimal) 
 
Write the data to the servo motor speed data of point table No.1 by turning on X20. 
The respond code at instruction code execution is set to D2. 
 
Turns on instruction code execution demand 
(RY29).
Reads respond code (RWr6) to D2 when 
instruction code execution completion (RX29) 
turns on.
Checks data link status of station No.2.
Writes speed data (H8D01) of point table No.1 
to RWw6, and speed data (K100) to RWw7.
Write 
command
In position
Turns off instruction code execution demand 
(RY29).