5 -  1 
5. OPERATION 
5. OPERATION 
 WARNING 
Do not operate the switches with wet hands. You may get an electric shock. 
 
 CAUTION 
Before starting operation, check the parameters. Some machines may perform 
unexpected operation. 
Take safety measures, e.g. provide covers, to prevent accidental contact of hands 
and parts (cables, etc.) with the servo amplifier heat sink, regenerative resistor, 
servo motor, etc. since they may be hot while power is on or for some time after 
power-off. Their temperatures may be high and you may get burnt or a parts may 
damaged. 
During operation, never touch the rotating parts of the servo motor. Doing so can 
cause injury. 
 
5.1 Switching power on for the first time 
When switching power on for the first time, follow this section to make a startup. 
 
5.1.1 Startup procedure 
Wiring check 
 
 
 
Check whether the servo amplifier and servo motor are wired 
correctly using visual inspection, DO forced output function 
(Section 7.7.4, 8.5.7 (4)), etc. (Refer to section 5.1.2.) 
Surrounding environment check 
 
 
 
Check the surrounding environment of the servo amplifier and 
servo motor. (Refer to section 5.1.3.) 
Parameter setting 
 
 
 
Set the parameters as necessary, such as the used control 
mode and regenerative option selection with the parameter unit 
or MR Configurator. (Refer to chapter 6.) 
Test operation of servo motor 
alone in test operation mode 
 
 
 
For the test operation, with the servo motor disconnected from 
the machine and operated at the speed as low as possible, and 
check whether the servo motor rotates correctly. (Refer to 
sections 7.7 and 8.5.7.) 
Test operation of servo motor 
alone by commands 
 
 
 
For the test operation with the servo motor disconnected from 
the machine and operated at the speed as low as possible, and 
check whether the servo motor rotates correctly. 
Test operation with servo motor 
and machine connected 
 
 
 
Connect the servo motor with the machine, give operation 
commands from the host command device, and check machine 
motions. 
Gain adjustment 
 
 
 
Make gain adjustment to optimize the machine motions. (Refer 
to chapter 9.) 
Actual operation 
 
 
 
 
 
Stop 
 
Stop giving commands and stop operation.