6. PARAMETERS 
 
No.  Symbol 
Name and function 
Initial 
value 
Unit 
Setting 
range 
PD20  *DOP1  Function selection D-1 
Select the stop processing at forward rotation stroke end (LSN)/reverse rotation 
stroke end (LSN) OFF and the base circuit status at reset (RY(N 1)A or 
RY(n 3)A) ON. 
Stopping method used when forward rotation
stroke end (LSP), reverse rotation stroke 
end (LSN) device or software limit is valid
0: Sudden stop (home position erased)
1: Slow stop (home position erased)
2: Slow stop (Deceleration to a stop by deceleration time constant)
3: Sudden stop (Stop by remaining move distance clear)
0
Stopping method used when software limit is valid
0: Sudden stop (home position erased)
1: Slow stop (home position erased)
2: Slow stop (Deceleration to a stop by deceleration time constant)
3: Sudden stop (Stop by remaining move distance clear)
Selection of base circuit status at reset (RY(n+1)A or RY(n+3)A)ON
0: Base circuit not switched off
1: Base circuit switched off
 
As in the following parameter settings, when the home position is lost by the 
forward rotation stroke end, reverse rotation stroke end, or the software limit 
detection, the home position return completion (ZP) turns on by turning OFF/ON 
the servo-on (RYn0). In this case, there is no need to perform the home position 
return again. 
1. In absolute position detection system 
Parameter No.PA03:       1 (Select the absolute position detection system) 
Parameter No.PA01:       0 (Select the absolute value command system) 
2. In incremental system 
Parameter No.PA03:       0 (Select the incremental system) 
Parameter No.PA01:       0 (Select the absolute value command system) 
Parameter No.PA04:       1 (Follow-up valid) 
0010h   Refer 
to 
name and 
function 
column. 
PD21 
 
For manufacturer setting 
Do not change this value by any means. 
0000h  
 
PD22  *DOP3  Function selection D-3 
Set the clear (RYnF). 
0 0 0
Clear (RYnF) selection
0: Droop pulses are cleared on the leading
edge.
1: While on, droop pulses are always cleared.
 
0000h   Refer 
to 
name and 
function 
column. 
PD23 
 
For manufacturer setting 
Do not change this value by any means. 
0000h