7 -  22 
7. MR Configurator 
 
(7) Servo motor software forced stop ( f) ) 
Click the "Software forced stop" button to stop the servo motor rotation immediately. When the "Software 
forced stop" button is enabled, the "Start" button cannot be used. Click the "Software forced stop" button 
again to make the "Start" button enabled. 
 
(8) Single-step feed window closing ( g) ) 
Click the "Close" button to cancel the single-step feed mode and close the window. 
 
(9) Switching to CC-Link operation mode 
To switch from the test operation mode to the CC-Link operation mode, turn OFF the power of the servo 