Справочник Пользователя для Mitsubishi Electronics MR-J3

Скачать
Страница из 668
 
 
9 -  4 
9. GENERAL GAIN ADJUSTMENT 
 
9.2.2 Auto tuning mode operation 
The block diagram of real-time auto tuning is shown below. 
Servo
motor
Command
Automatic setting
Loop gains
PG1,VG1
PG2,VG2,VIC
Current 
control
Current feedback
Load inertia 
moment
Encoder
Position/speed 
feedback
Real-time auto 
tuning section
Speed feedback
Load inertia 
moment ratio 
estimation section
Gain 
table
Set 0 or 1 to turn on.
Switch
Response 
setting
Gain adjustment mode 
selection
Parameter No.PA08 Parameter No.PA09
0 0 0
Parameter No.PB06
Load inertia moment 
ratio estimation value
 
When a servo motor is accelerated/decelerated, the load inertia moment ratio estimation section always 
estimates the load inertia moment ratio from the current and speed of the servo motor. The results of 
estimation are written to parameter No.PB06 (the ratio of load inertia moment to servo motor). These results 
can be confirmed on the status display screen of the MR Configurator section. 
If the value of the load inertia moment ratio is already known or if estimation cannot be made properly, chose 
the "auto tuning mode 2" (parameter No.PA08: 0002) to stop the estimation of the load inertia moment ratio 
(Switch in above diagram turned off), and set the load inertia moment ratio (parameter No.34) manually. 
From the preset load inertia moment ratio (parameter No.PB06) value and response level (parameter 
No.PA09), the optimum loop gains are automatically set on the basis of the internal gain tale. 
The auto tuning results are saved in the EEP-ROM of the servo amplifier every 60 minutes since power-on. At 
power-on, auto tuning is performed with the value of each loop gain saved in the EEP-ROM being used as an 
initial value. 
 
POINT 
 
If sudden disturbance torque is imposed during operation, the estimation of 
the inertia moment ratio may malfunction temporarily. In such a case, choose 
the "auto tuning mode 2" (parameter No.PA08: 0002) and set the correct load 
inertia moment ratio in parameter No.PB06. 
When any of the auto tuning mode 1 and auto tuning mode settings is 
changed to the manual mode 2 setting, the current loop gains and load inertia 
moment ratio estimation value are saved in the EEP-ROM.