Справочник Пользователя для Mitsubishi Electronics MR-J3

Скачать
Страница из 668
 
 
10 -  15 
10. SPECIAL ADJUSTMENT FUNCTIONS 
 
(2) When you choose changing by droop pulses 
(a) Setting 
 
Parameter 
No. 
Abbreviation Name 
Setting  Unit 
PB07 
PG1 
Model loop gain 
100 rad/s 
PB06 GD2 
Ratio of load inertia moment to servo motor 
inertia moment 
4.0 
Multiplier
( 1) 
PB08 
PG2 
Position loop gain 
120 rad/s 
PB09 
VG2 
Speed loop gain 
3000 rad/s 
PB10 
VIC 
Speed integral compensation 
20 
ms 
PB29 GD2B 
Gain changing ratio of load inertia moment to 
servo motor inertia moment 
10.0 
Multiplier
( 1) 
PB30 
PG2B 
Gain changing position loop gain 
84 
rad/s 
PB31 
VG2B 
Gain changing speed loop gain 
4000 rad/s 
PB32 
VICB 
Gain changing speed integral compensation 
50 
ms 
PB26 
CDP 
Gain changing selection 
0003 
(Changed by droop pulses) 
 
PB27 
CDS 
Gain changing condition 
50 
pulse 
PB28 
CDT 
Gain changing time constant 
100 ms 
 
(b) Changing operation 
CDT  100ms
0
Droop pulses [pulses]
Change of each gain
CDS
CDS
Before-changing gain
After-changing gain
Command pulse
Droop pulses
 
Model loop gain 
100 
Ratio of load inertia moment 
to servo motor inertia moment 
4.0 
 10.0   4.0 
 10.0 
Position loop gain 
120 
 84   120 
 84 
Speed loop gain 
3000 
 4000   3000 
 4000 
Speed integral compensation 
20 
 50   20 
 50