Справочник Пользователя для Mitsubishi Electronics MR-J3

Скачать
Страница из 668
 
 
11 -  11 
11. TROUBLESHOOTING 
 
Display Name 
Definition 
Cause 
Action 
(Note) 
888 
Watchdog 
CPU, parts faulty. 
Fault of parts in servo amplifier. 
Checking method
Alarm (888) occurs if power is 
switched on after disconnection of 
all cables but the control circuit
power supply cable.
 
Change the servo amplifier. 
Note. At power-on, "888" appears instantaneously, but it is not an error. 
 
11.4.3 Remedies for warnings 
CAUTION 
If an absolute position counter warning (AE3) occurred, always make home 
position setting again. Not doing so may cause unexpected operation. 
 
POINT 
 
When any of the following alarms has occurred, do not resume operation by 
switching power of the servo amplifier OFF/ON repeatedly. The servo amplifier 
and servo motor may become faulty. If the power of the servo amplifier is 
switched OFF/ON during the alarms, allow more than 30 minutes for cooling 
before resuming operation. 
Excessive regenerative warning (AE0) 
Overload warning 1 (AE1) 
 
If AE6 occur, the servo off status is established. If any other warning occurs, operation can be continued but an 
alarm may take place or proper operation may not be performed. 
Remove the cause of warning according to this section. Use the MR Configurator to refer to a factor of warning 
occurrence. 
 
Display Name 
Definition 
Cause 
Action 
Positioning operation 
was performed 
without home 
position return. 
1. Positioning operation was performed 
without home position return. 
Perform home position return. 
In
 in
cr
em
ent
al
 sys
te
m
 
Home position return 
ended abnormally. 
2. Home position return speed could not be 
decreased to creep speed. 
3. Limit switch was actuated during home 
position return starting at other than 
position beyond dog. 
Check home position return 
speed/creep speed/moving 
distance after proximity dog. 
Positioning operation 
was performed 
without home 
position setting. 
1. Positioning operation was performed 
without home position setting. 
Perform home position setting. 
Home position 
setting ended 
abnormally. 
2. Home position setting speed could not be 
decreased to creep speed. 
3. Limit switch was actuated during home 
position setting starting at other than 
position beyond dog. 
Check home position setting 
speed/creep speed/moving 
distance after proximity dog. 
4. Voltage drop in encoder 
(Battery disconnected.) 
After leaving the alarm occurring 
for a few minutes, switch power 
off, then on again. Always make 
home position setting again. 
5. Battery voltage low 
A90 Home 
position 
return incomplete 
In
 abs
ol
ut
e po
si
tion det
ec
tion sys
te
m
 
Operation was 
performed without 
making home 
position setting while 
an absolute position 
erase (A25) is being 
occurred. 
6. Battery cable or battery is faulty. 
Change the battery.  
Always make home position 