13. CHARACTERISTICS 
 
13. CHARACTERISTICS 
13.1 Overload protection characteristics 
An electronic thermal relay is built in the servo amplifier to protect the servo motor and servo amplifier from 
overloads. Overload 1 alarm (A50) occurs if overload operation performed is above the electronic thermal relay 
protection curve shown in any of Figs 13.1. Overload 2 alarm (A51) occurs if the maximum current flew 
continuously for several seconds due to machine collision, etc. Use the equipment on the left-hand side area of 
the continuous or broken line in the graph. 
In a machine like the one for vertical lift application where unbalanced torque will be produced, it is 
recommended to use the machine so that the unbalanced torque is 70% or less of the rated torque. 
When you carry out adhesion mounting of the servo amplifier, make circumference temperature into 0 to 45  
(32 to 113 ), or use it at 75% or smaller effective load ratio. 
1000
100
10
1
0.1
0
50
150
200
250
300
100
(Note) Load ratio [%]
O
p
er
at
ion t
ime[
s]
During operation
During servo lock
 
MR-J3-10T(1) 
1000
100
10
1
0.1
0
50
150
200
250
300
100
(Note) Load ratio [%]
O
perat
io
n
 ti
m
e
[s
]
During operation
During servo lock
MR-J3-20T(1) MR-J3-40T(1) 
MR-J3-60T(4) to MR-J3-100T(4) 
 
1000
100
10
1
0.1
0
50
150
200
250
300
100
(Note) Load ratio [%]
O
p
er
at
ion t
ime[
s]
During operation
During servo lock
 
MR-J3-200T(4) MR-J3-350T(4) 
(Note) Load ratio [%]
Operat
io
n
 ti
m
e
[s
]
10000
1000
100
10
1
0
50
150
200
250
100
300
During operation
During servo lock
MR-J3-500T(4) MR-J3-700T(4)