14. OPTIONS AND AUXILIARY EQUIPMENT 
 
14.3.1 Selection 
Use a combination of servo amplifier, brake unit and resistor unit listed below.  
 
Brake unit 
Resistor unit 
Number of 
connected 
units 
Permissible 
continuous 
power [kW] 
Total 
resistance 
[ ] 
Applicable servo 
amplifier 
FR-BU2-15K FR-BR-15K 
0.99 
8 MR-J3-500T 
(Note) 
200V  
class     2 
(parallel) 
1.98 
MR-J3-500T 
MR-J3-700T 
MR-J3-11KT 
MR-J3-15KT 
 FR-BU2-30K 
FR-BR-30K 
1.99 
MR-J3-500T 
MR-J3-700T 
MR-J3-11KT 
MR-J3-15KT 
 FR-BU2-55K 
FR-BR-55K 
3.91 
MR-J3-11KT 
MR-J3-15KT 
MR-J3-22KT 
  
MT-BR5-55K 
5.5 
MR-J3-22KT 
400V 
class 
FR-BU2-H30K FR-BR-H30K 
1.99 
16 MR-J3-500T4 
MR-J3-700T4 
MR-J3-11KT4 
 FR-BU2-H55K  FR-BR-H55K 
3.91 
MR-J3-11KT4 
MR-J3-15KT4 
MR-J3-22KT4
 
 FR-BU2-H75K  MT-BR5-H75K 
7.5 
6.5  MR-J3-22KT4 
Note. The combination is limited only when using with the servo motors HC-LP302, HC-RP353, HA-LP502 or HC-UP352. 
 
14.3.2 Brake unit parameter setting 
Normally, when using the FR-BU2-(H), changing parameters is not necessary. Whether a parameter can be 
changed or not is listed below. 
 
Parameter 
No. Name 
Change 
possible/ 
impossible 
Remarks 
Brake mode switchover 
Impossible 
Do not change the parameter. 
Monitor display data selection 
Possible 
Refer to the FR-BU2-(H) Brake Unit 
Instruction Manual. 
Input terminal function selection 1 
Input terminal function selection 2 
77 Parameter 
write 
selection 
78 Cumulative 
energization 
time 
carrying-over times 
CLr Parameter 
clear 
ECL  Alarm history clear 
C1 
For manufacturer setting 
Impossible 
Do not change the parameter.