15. COMMUNICATION FUNCTION 
 
15.5.7 Input devices ON/OFF (test operation) 
Each input devices can be turned on/off for test operation. when the device to be switched off exists in the 
external input signal, also switch off that input signal. 
Send command [9] [2], data No. corresponding to the input device and data. 
Command 
Data No. 
Set data 
[0][0] 
[9][2] 
[0][1] 
See below 
b31
b0
0: OFF
1: ON
b1
Command of each bit is transmitted to the slave
station as hexadecimal data.
 
 
Data No. [0][0] 
Data No. [0][1] 
bit 
Device name 
Symbol
Device name 
Symbol 
0 Servo-on 
SON 
Forward rotation stroke end 
LSP 
Reverse rotation stroke end 
LSN 
3  
 
Internal torque limit selection 
TL1 
5 Proportion 
control 
PC 
6 Reset 
RES 
7 Clear 
CR 

10 
 
 
11 Forward 
rotation 
start 
ST1 
12 Reverse 
rotation 
start 
ST2 
13 
14 
15 
16 
 
 
17 Automatic/manual 
selection 
MD0 
18 Proximity 
dog 
DOG 
19 
20 
21 
22 
 
 
23 Override 
selection 
OVR 
 
 
24 
Temporary stop/Restart 
TSTP  Point table No. selection 1 
DI0 
25 
Point table No. selection 2 
DI1 
26 
 
 
Point table No. selection 3 
DI2 
27 
Gain changing 
CDP  Point table No. selection 4 
DI3 
28 
Point table No. selection 5 
DI4 
29 
Point table No. selection 6 
DI5 
30 
Point table No. selection 7 
DI6 
31 
 
 
Point table No. selection 8 
DI7