Справочник Пользователя для Mitsubishi Electronics MR-J3

Скачать
Страница из 668
 
 
16 -  7 
16. INDEXER POSITIONING OPERATION 
 
Device No. 
Signal name 
(Device name) 
Description  
1 station 
occupied 
2 stations 
occupied 
Remarks 
Monitor output execution 
demand 
When RYn8 is turned ON, the following data and signals are 
set. At the same time, RXn8 turns ON. While RYn8 is ON, the 
monitor values are kept updated. 
1) When 1 station is occupied 
Remote register RWrn: Data demanded by Monitor 1 
(RWwn) 
Remote register RWrn 1: Data demanded by Monitor 2 
(RWwn 1) 
Remote register RWrn 2: Respond code indicating normal 
or error 
2) When 2 stations are occupied 
Remote register RWrn: Lower 16 bits of data demanded by 
Monitor 1 (RWwn) 
Remote register RWrn 1: Upper 16 bits of data demanded 
by Monitor 1 (RWwn) 
Remote register RWrn 5: Lower 16 bits of data demanded 
by Monitor 2 (RWwn 2) 
Remote register RWrn 6: Upper 16 bits of data demanded 
by Monitor 2 (RWwn 2) 
Remote register RWrn 2: Respond code indicating normal 
or error 
RYn8 RYn8 
 
Instruction code execution 
demand 
Turning RYn9 ON executes the processing corresponding to 
the instruction code stored in remote register RWwn 2. 
After completion of instruction code execution, the respond 
code indicating normal or error is set to RWrn 2. At the same 
time, RXn9 turns ON. 
Refer to section 16.2.4 for details. 
RYn9 RYn9 
 
Next station selection 1 
 
Select the station number by using RYnA to RY(n 2)5. 
 
RYnA RYnA 
Next station selection 2 
 
(Note 1) Remote input 
RYnB RYnB 
 
 
 
 
Next station selection 3 
 
Station 
No. 
RY 
(n+2)5 
RY 
(n+2)4 
RY 
(n+2)3
RYnE RYnD RYnC RYnB RYnA
RYnC RYnC 
 
 
0 0 0 0 0 0 0 0 0 
 
 
Next station selection 4 
 
1 0 0 0 0 0 0 0 1 
RYnD RYnD 
 
 
2 0 0 0 0 0 0 1 0 
 
 
Next station selection 5 
 
3 0 0 0 0 0 0 1 1 
RYnE RYnE 
 
 
4 0 0 0 0 0 1 0 0 
 
 
Next station selection 6 
 
 
 
 
 
 
 
 
 
 
RY(n 2)3 
 
 
 
 
 
 
 
 
 
 
 
 
 
Next station selection 7 
 
 
 
 
 
 
 
 
 
 
RY(n 2)4 
 
 
 
 
 
 
 
 
 
 
 
 
 
Next station selection 8 
 
 
 
 
 
 
 
 
 
 
RY(n 2)5 
 
  254 1 1 1 1 1 1 1 0 
 
 
 
(Note 2) 
1 1 1 1 1 1 1 1 
 
 
 
Note 1. 0: OFF 
1: ON 
2. When setting “1” for all RYnA to RYnE and RY(n 2)3 
to RY(n 2)5, the station warning (A97) occurs.