16. INDEXER POSITIONING OPERATION 
 
16.8.2 JOG operation 
(1) Setting 
Set the devices and parameters as indicated below for the purpose of use. In this case, the next station 
selection 1 to 8 (RYnA to RYnE and RY(n 2)3 to RY(n 2)5) and the speed selection 1 to 3 (RY(n 2)C 
to RY(n 2)E) are invalid. 
 
Item Device/Parameter 
Setting 
description 
Indexer positioning operation 
selection 
Parameter No.PA01 
1
: Select the indexer positioning 
operation. 
Operation mode selection 1 (RYn6) 
Turn on RYn6 
Manual operation mode selection 
Operation mode selection 2 (RYn7) 
Turn off RYn7 
JOG operation selection 
Parameter No.PC45 
Set it to "
1". 
Station No. direction 
Parameter No.PA14 
Refer to (2) in this section. 
JOG speed 
Point table No.1 
The setting is the same as for the indexer JOG 
operation. Refer to (2) in section 16.8.1. 
Acceleration/deceleration time 
constant 
Point table No.1 
Use the acceleration/deceleration time constant 
in the point table No.1. 
 
(2) Operation 
Turn on the start (RYn1) to operate the servo motor with the servo motor speed, acceleration time constant, 
and deceleration time constant set in the point table No.1. Turning off RYn1 makes the servo motor 
decelerate to stop regardless of stations. For the rotation direction, refer to (2) in section 16.8.1. 
 
(3) Timing chart 
The following timing chart shows an example when executing the indexer JOG operation from the status 
where the servo motor is at a stop on the station No.0 when the servo-on is turned on. 
6ms or more
(Note)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
4ms or more
No.0
Out of in-position range
Torque limit value to be effective
Operation mode selection 2
(RYn7)
Operation mode selection 1
(RYn6)
Start (RYn1)
Rotation direction specifying
(RYn2)
Servo motor speed
In position (RXn1)
Parameter No.PA11, PA12
Parameter No.PC35
Parameter No.PA11, PA12
Parameter No.PC35
Parameter No.PC35
Forward 
rotation 
Reverse 
rotation 
0r/min
Station output 1 to 8
(RX(n   2)2 to RX(n   2)9)
 
Note. Torque limit delay time can be set in the parameter No.PD26.