 Diagnostics
 
19
Ethernet Link 
Status light 
does not 
light.
Check the following:   
Make sure that the hub is turned on.
Check all connections at the Ethernet 
controller and the hub.
Check the cable.  A crossover cable 
is required unless the hub has an 
X
 
designation.
Use another port on the hub.
If the hub does not support auto-
negotiation, manually configure the 
Ethernet controller to match the hub.
If you manually configured the duplex 
mode, make sure that you also 
manually configure the speed.
Run diagnostics on the LEDs.
The Ethernet 
Transmit/ 
Receive 
Activity light 
does not 
light.
Check the following:   
Note: The Ethernet Transmit/Receive 
Activity LED illuminates only when 
data is sent to or by this Ethernet 
controller.
Make sure that you have loaded the 
network device drivers.
The network might be idle.  Try 
sending data from this workstation.
Run diagnostics on the LEDs.
The function of this LED can be 
changed by device driver load 
parameters.  If necessary, remove 
any LED parameter settings when 
you load the device drivers.
Data is 
incorrect or 
sporadic.
Check the following:   
Make sure that you are using 
Category 5 cabling when operating 
the server at 100 Mbps.
Make sure that the cables do not run 
close to noise-inducing sources like 
fluorescent lights.
Table 1. Ethernet troubleshooting chart 
Ethernet 
controller 
problem
Suggested Action