1
General checkout
The server diagnostic programs are stored in upgradable 
read-only memory (ROM) on the system board.  These pro-
grams are the primary method of testing the major compo-
nents of the server: the system board, Ethernet controller, 
video controller, RAM, keyboard, mouse (pointing device), 
diskette drive, serial ports, hard drives, and parallel port.  
You can also use them to test some external devices.  See 
“Diagnostic programs and error messages” on page 10.
Also, if you cannot determine whether a problem is caused 
by the hardware or by the software, you can run the diag-
nostic programs to confirm that the hardware is working 
properly.
When you run the diagnostic programs, a single problem 
might cause several error messages.  When this occurs, 
work to correct the cause of the first error message.  After 
the cause of the first error message is corrected, the other 
error messages might not occur the next time you run the 
test.  
A failed system might be part of a shared DASD cluster (two 
or more systems sharing the same external storage 
device(s)).  Prior to running diagnostics, verify that the failing 
system is not part of a shared DASD cluster.
A system might be part of a cluster if:
The customer identifies the system as part of a cluster.
One or more external storage units are attached to the 
system and at least one of the attached storage units is 
additionally attached to another system or unidentifi-
able source.
One or more systems are located near the failing sys-
tem.
If the failing system is suspected to be part of a shared 
DASD cluster, all diagnostic tests can be run except diag-
nostic tests which test the storage unit (DASD residing in the 
storage unit) or the storage adapter attached to the storage 
unit.
Notes:
1. For systems that are part of a shared DASD cluster, run 
one test at a time in looped mode.  Do not run all tests 
in looped mode, as this could enable the DASD diag-
nostic tests.
2. If multiple error codes are displayed, diagnose the first 
error code displayed.
3. If the computer hangs with a POST error, go to the 
4. If the computer hangs and no error is displayed,  go to 
5. Power supply problems, see “Symptom-to-FRU index” 
6. Safety information, see “Safety information” on page