Справочник Пользователя для Lucent Technologies 8.2

Скачать
Страница из 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Screen reference 
1003
Trunk Group 
17
Data Restriction
Short Holding Threshold
This field appears when the ACA Assignment field is 
y
.
Glare Handling
This field determines what the switch will do when glare occurs. This field 
appears when the Direction field is 
two-way
 and the outgoing side of the Trunk 
Type field is either 
…/wink
 or
 …/delay
.
If you enter 
control
 or 
backoff
, and ports for the trunk group are not capable of 
detecting glare, warnings are generated. The following circuit packs can detect 
glare: TN767 (all releases), TN760C (or later releases), and TN464C (or later 
releases).
Abandoned Call Search
Use this field when the Trunk Type field is 
ground-start
. Abandoned Call Search 
is designed to work with analog ground-start CO trunks that do not provide 
disconnect supervision. Your central office must support Abandoned Call Search 
for the feature to work properly. If your central office provides disconnect 
supervision, you do not need to use the Abandoned Call Search feature. 
Valid entries
Usage
y/n 
Enter 
y
 to prevent features from generating tones on a data 
call that would cause erroneous data transmission.
Valid entries
Usage
0
 to 
30
Enter the number of times the system will record a short 
holding call before alerting an attendant to the possibility of a 
faulty trunk. 
Valid entries
Usage
control
Your switch will seize the trunk and proceed with call setup. 
The other switch will find another trunk.
backoff
The other switch will seize the trunk proceed with call setup. 
Your switch will find another trunk.
none
 
Valid entries
Usage
y/n 
Enter 
y
 if this trunk group will conduct an Abandoned Call 
Search to identify ghost calls.