Справочник Пользователя для Unibrain 785

Скачать
Страница из 72
Unibrain Fire-i 580/780/785/980 Operation Manual 
 
Page 28 
 
 
 
 
3.11.  Gain   
Gain refers to the amount of the CCD output signal amplification where gain and shutter have similar effect on the 
image.    Manual and Automatic gain mode are supported and manual adjustment is possible for the following range. 
For Gain control inquiry and status register, follow the same definition as “BRIGHTNESS” 
 
Camera Type 
Step Range 
Range in dB 
Increment Length 
Monochrome Camera 
0 ~ 511 
0 ~ 18 
approx.  0.0358 dB/step 
Color Camera 
0 ~ 511 
0 ~ 18 
approx.  0.0358 dB/step 
3.12.  Trigger & Strobe   
The cameras support external trigger by receiving input through the external trigger port. The falling edge and rising 
edge can be detected as trigger according to the modes it supports as per the following table. A software trigger can 
also be used that issues a trigger signal via a software command. Software trigger is supported in modes 0 and 15. 
Trigger 
Edge 
Rising Edge or Falling Edge 
Mode 
Fire-i 580/785/780 
0, 1, 2, 3, 4, 5, 15 
Method 
Optocoupler (Photo-coupler) 
Source 
External or Software Trigger 
  Inquiry Register 
Address 
Name 
Field 
Bit 
Description 
530h 
TRIGGER
_INQ 
Presence_Inq 
[0] 
Presence of this feature 
Abs_Control_Inq 
[1] 
Capability of control with absolute value 
[2..3] 
Reserved 
ReadOut_Inq 
[4] 
Capability of reading the value of this feature 
On/Off_Inq 
[5] 
Capability of switching this feature On and OFF 
Polarity_Inq 
[6] 
Capability of changing polarity of trigger input 
 
[7..15] 
Reserved 
Trigger_Mode0_Inq 
[16] 
Presence of Trigger Mode0 
Trigger_Mode1_Inq 
[17] 
Presence of Trigger Mode1 
Trigger_Mode2_Inq 
[18] 
Presence of Trigger Mode2 
Trigger_Mode3_Inq 
[19] 
Presence of Trigger Mode3 
 
[20..31] 
Reserved