DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-456
CUST-ALM (Customer-Provided Alarming Device) 
9
Customer-Provided Alarming Device Test (#115)
The Customer-Provided Alarming Device (CPAD) Test closes the relay that 
activates the CPAD for 1-minute only within the port network specified. If it takes 
longer than 1-minute to check that the CPAD has been activated, the Repeat field 
on the test customer-alarm UUC command can be used to close the relay for 
up to 99 minutes. Note that when the repeat option is used, the results for Test 
#115 come back immediately and, for each test that passed, the CPAD is kept on 
for that many minutes. The CPAD does not go off after 1-minute and then come 
back on. Instead, the CPAD is kept on continuously for the entire time. If the 
CPAD is being activated and deactivated in a flickering fashion, there is a 
problem with either the CPAD, or the SYSAM, or the EPN Maintenance circuit 
pack.
Table 9-189.
TEST #115 Customer-Provided Alarming Device Test 
Error 
Code
Test 
Result
Description/ Recommendation
Any
ABORT
Internal system error
1. Retry the command at 1-minute intervals for a maximum of 5 times.
PASS
The switch software successfully sent the request to the SYSAM or EPN 
Maintenance circuit pack to turn on the CPAD. The CPAD must be 
physically inspected to verify that it is working. If the CPAD is working but 
the customer has complained that the CPAD did not indicate a system 
alarm when it occurred, then check the administered alarm level for turning 
on the CPAD. This is on the display system-parameter maintenance form. 
Compare this level with the customer’s specifications. If the level does not 
match the customer’s specifications, change it using the change 
system-parameter maintenance
 form. If Test #115 passes, and the CPAD 
is not being activated, check the connection of the CPAD to the SYSAM or 
EPN Maintenance circuit pack. If the CPAD can be activated but cannot be 
deactivated, first check to make sure Emergency Transfer is not activated in 
the affected port network via the status port-network command. 
Emergency Transfer can be forced to manual OFF via the Emergency 
Transfer switch on the SYSAM or EPN Maintenance circuit pack. If 
Emergency Transfer is OFF and the CPAD still cannot be deactivated, 
check the administered levels for the CPAD via the display 
system-parameter maintenance
 form and compare against the alarm 
levels currently present in the system (display alarms command).