Maintenance Object Repair Procedures
9-734
DUPINT (Duplication Interface Circuit Pack)
9
b. A local DUPINT FIFO overflow condition has been reported. If this alarm
cannot be cleared by replacing the active Duplication Interface circuit
pack, escalate the problem.
pack, escalate the problem.
c. In-line errors have been reported from the DUPINT driver. If this alarm
cannot be cleared by replacing the active Duplication Interface circuit
pack, escalate the problem.
pack, escalate the problem.
System Technician-Demanded Tests: Descriptions
and Error Codes
and Error Codes
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the
error codes associated with the
Control Register Test for example, you may also
clear errors generated from other tests in the testing sequence.
51
The Active DUPINT Reset Test failed because the HFAIL bit stayed set
after reset.
after reset.
52
The Active DUPINT Reset Test failed because the state of health could
not be restored after the reset.
not be restored after the reset.
55
The Active DUPINT Reset Test failed because shadowing could not be
turned off after the board was successfully reset.
turned off after the board was successfully reset.
Aux
Data
Cause of Error
23
DUPINT driver suicide
24
DUPINT driver loss of interrupt path
27
DUPINT driver no handshake path for processes
28
DUPINT driver no handshake path for drivers
29
DUPINT driver no control path
30
DUPINT driver main receive failed
Aux
Data
Cause of Error