Procedures for Restoring the System Printer Link
1. Determine the status of the System Printer Link via the status sp-link 
command. Verify that the System Printer Link is not busied out for 
maintenance. This is indicated by a 
no
 in the 
Maintenance Busy?
 field. 
If the System Printer Link has been busied out, issue the release sp-link 
command. If the link is 
down
, proceed to Step 2.
2. Issue the display system feature command to determine the location of 
the System Printer Link.
Enter the status data-module <extension> command and verify that the 
data extension is in-service/idle. If the data extension is 
not available, refer 
to the 
Port
 field. Look for errors and/or alarms on the circuit pack with 
which this extension is associated. Follow repair instructions for the 
appropriate MO. Continue with Step 3.
3. Verify the availability of the external SYS-PRNT output device. Make sure 
that the output device is 
on-line and ready-for-service. Check the physical 
connectivity between the Data Module and the SYS-PRNT output device.
4. Verify that there is at least one system port available. The System Printer 
Link can not be established unless there is a system port available. Refer 
to “PDATA-PT” for more information on system ports.
5. If the problem is not found in the above steps, check the system port for 
any problems. Refer to “PDATA-PT” for description about system port and 
its connectivity.
It should be noted that when restoring the System Printer link it is necessary to 
execute tests on different maintenance objects that comprise the System Printer 
link. It is recommended that you busy out the System Printer link before trying to 
restore the link. When the System Printer Link is busied out, all System Printer 
Link maintenance actions are deactivated, and interference with tests of other 
MOs is prevented.