DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-152
ATM-BCH (ATM B-Channel Trunk) 
9
b. Error Type 129: the far-end switch changed its ISDN service state to either 
out-of-service or maintenance. This may be a temporary condition 
because the far-end is testing that trunk or a hardware problem with the 
trunk. Outgoing calls may not be allowed over that trunk.
1. Investigate the trunk status (status trunk 
grp#/mbr#).
c. Error Type 130: the circuit pack has been removed or has been insane for 
more than 11 minutes.
1. Reinsert or replace the circuit pack to clear the error.
d. Error Type 257: SETUP received for a B-channel that is in an invalid 
service state. Service states may be incompatible at the two ends of the 
trunk. A normal call was received while the B-channel was MTC/FE, 
MTC/NE, OOS/FE, or OOS/NE or a test call was received while the 
B-channel was OOS/FE or OOS/NE.
e. Error Type 513: RELease COMplete message received with cause value 
82 (nonexistent channel). The B-channel may not be administered at the 
far end. The trunk has been placed in the OOS/FE state.
f. Error Type 769:  inconsistent SERVice or SERVice ACKnowledge 
message. Possible causes:
SERVice or SERVice ACKnowledge message received containing a 
change status that is more available than the previously-transmitted 
SERVice message.
Unsolicited SERVice ACKnowledge message received containing a 
change status that does not match the current B-channel state. 
ISDN-PRI service-state negotiation rules have been violated and may 
indicate that a pending service-state audit is failing. The system
cancels the maintenance timer
increments the Service State Audit counter
attempts a Service State Audit
When running the Short Test Sequence, pay close attention to the results 
of the Service State Audit Test (#256).
g. Error Type 1793: TN230x circuit pack has failed. The maintenance system
places the trunk in the OOS/NE state
sends a SERvice message to the far-end (if possible) containing a 
change status of OOS for the B-channel
returns the trunk to service when the ATM trunk circuit pack reports 
the failure cleared
h. Error Type 3073: Service State Audit attempt failed (see Test #256). Calls 
can be received but not placed until the test passes and the trunk state 
returns to In-Service.
1. Check the trunk status (status trunk 
grp#/mbr#).