DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-31
Off-Premises or Out-of-Building Stations 
5
Figure 5-15.
Connections for Up to 8 Out-of-Building Analog Telephones
 shows the connections for up to 24 off-premises analog telephones. 
Concentrations of analog line pairs are used at both buildings to minimize the 
off-premises wiring required. At the MDF, connect jumpers between 1 
row/connecting block in the white field and up to 3 rows/connecting blocks in the 
purple field. At the station location, a WP-90929, List 1 Concentrator Cable is 
used. There are 8 station appearances on each of the 3 fingers of the 
concentrator cable.
Figure Notes
1. Locally Engineered Cables and Equipment
2. Out-of-Building Wiring
3. 25-Pair Connector
4. Multi-Pair Protector Units (Primary 
Protectors with Heat Coils or Equivalent with 
Sneak Current Protection)
5. 356A Adapter
6. B25A Cable
7. Out-Of-Building Analog Telephones
8. Part of MDF
9. Station Side
10. System Side
11. White Field
12. Purple Field
13. Cross-Connect Jumpers
14. Tip and Ring Wires
15. To TN2183, TN769, TN742, TN746B, 
or Analog Line Circuit Pack
8
7
1
9
10
11
13
14
15
12
0043_0 RBP 062796
2
4
4
6
6
5
3