DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Option Switch Settings 
Page B-4
External Modem Option Settings 
B
Dial 
Command
This field has a default of “D” in a field 3 characters long. This field 
denotes the dialing command of the modem. This is a standard 
command. This field is not case sensitive. Default is upper case.
No Answer 
Time-Out
Most external modems provide a timer that abandons any outbound data 
call after a predetermined interval. Some modems disable this timer, 
allowing an outbound call to ring indefinitely. Paradyne does not provide 
this capability because it is undesirable to have an outbound call attempt 
to ring indefinitely. Therefore, the initialization string must contain the 
following ASCII string to set the “No-Answer Timer” to the maximum value: 
S7=255. The internal modem must have this parameter disabled or set to 
at least 255 seconds. This is a non-administrable parameter. 
For the modem connection, this parameter is the first initialization string to 
be transmitted to the modem. This field is visible on the administration 
form in display mode only. The new field is set to S7=255. This hardcoded 
constant can be overridden for type approval applications, specifically in 
the United Kingdom and other Western European nations, by the use of 
the “Misc. Init. Param:” field. (S7=255)
Table B-1.
Modem Fields  — 
Continued
Modem 
Connection
 Description
Continued on next page