Справочник Пользователя для Pelco C290M-A (6/99)

Скачать
Страница из 12
6
PELCO Manual C290M-A (6/99)
Figure 7.  Locking Fixed Mount in Place
5.0  ADJUSTMENTS
To adjust the horizontal and vertical position of the
fixed mount perform the following steps:
1.
Remove dome as per instructions in Section 4.1.1,
step 3.
2.
Loosen the horizontal positioning lock-down knob;
then rotate mount to the desired position and re-
tighten knob.
3.
Loosen the vertical positioning lock-down knob
and adjust tilt table to desired position; then re-
tighten knob.
4.
Attach the dome to the drive as described in Sec-
tion 4.3, step 3, Camera/Lens Installation.
5.1  OPERATION
Upon completion of the fixed mount and camera/lens
installation and positioning adjustments of the fixed
mount, the Intercept Dome is ready for operation.
Reach into the back box and turn the power switch ON
(if applicable to your back box).
CAUTION
The fixed mount should never be installed
or removed when power switch is in the
ON position.
Now attach the bezel or trim ring to the back box as
shown in Figure 8. Align the three bezel pins with the
large hole in the back box brackets; push the bezel up
and rotate clockwise to latch.
Installation of your Intercept Dome is now complete
and dome is ready for operation.
4.2  LENS WIRING
Refer to back box manual, C456M, for wiring pinouts
and wire lens according to manufacturers instructions .
4.3  CAMERA/LENS INSTALLATION
Install the camera/lens you have selected for use with
the IDS08 series dome as follows:
1.
Attach camera/lens to the tilt table using the 1/4-
20 x 1/2" fastener (supplied), mounting through
the tilt table into the camera. Only snug the fas-
tener at this time to allow for camera/lens posi-
tioning.
2.
Connect camera power spade lugs and coax video
cable.
3.
Ensure there is sufficient initial clearance between
the camera/lens and dome as you carefully attach
dome to fixed mount. Align the two (2) ball studs
on the dome to the two (2) ball stud receivers on
the fixed mount and push dome until a snapping
sound occurs (refer to Figure 3).
4.
Position camera/lens and route wiring as neces-
sary to achieve clearances. This procedure may re-
quire removing and reattaching dome a few times
to obtain correct position.
5.
After satisfactory clearances have been achieved,
remove dome and tighten camera/lens fastener.