Troubleshooting
If the following instructions fail to solve your problem, contact Pelco Product Support at 1-800-289-9100 
(USA and Canada) or +1-559-292-1981 (international) for assistance. You should have the serial number 
from the product label available.
Do not try to repair the unit yourself. Opening it immediately voids any warranty. Leave maintenance and 
repairs to qualified technical personnel. Exchange the defective unit and return it for repair.
Table F.  Troubleshooting the IP110 Series (1 of 3)
Problem
Possible Cause
Suggested Remedy
No video
PoE power issue 
• Check Cat5 cable connection.
• Verify PoE is enabled.
• Disconnect the Cat5 cable from the PoE, and then 
reconnect the cable. Check the LED inside the back 
box to verify that it is flashing green, indicating the 
camera has power.
Power issue (24 VAC)
• Check the 24 VAC power supply connection.
• Disconnect the network cable, and then reconnect it 
to the camera. Check the LED inside the back box to 
verify that it is flashing green, indicating the camera 
has power.
Network connectivity 
issues
• Check network cable connections.
• Disconnect the network cable, and then reconnect it 
to the camera. Check the LED inside the back box to 
verify that it is flashing green.
• Replace network cable with new cable. 
Defective camera
• Check the camera’s 10-pin connector inside the back 
box to make sure it is connected.
• Use a service connector to check camera operation. 
Connect one end of the service connector to the 
service connector input inside the back box. Then 
connect the other end of the service connector to a 
monitor.
• Replace camera module with new camera. 
Image too dark/
black image
Installation error
• Make sure the lens cover in not installed.
• Make sure camera is not located in an environment 
with zero light.
• Use a service connector to check camera operation. 
Connect one end of the service connector to the 
service connector input inside the back box. Then 
connect the other end of the service connector to a 
monitor.
• Replace camera module with new camera.