Servicing
 
DISASSEMBLY
 
1. Disconnect the power from the enclosure.
2. Remove the mating connector from the rear of the enclosure by turning the outer ring counterclockwise until a click is felt; then pull the 
mating portion of the connector off. You may elect to remove the enclosure from its mount, which will make the disassembly process much 
easier.
3. Remove the center cap from the Schraeder valve. Refer to Figure 1.
4. Relieve internal enclosure pressure by depressing and holding down the center stem of the Schraeder valve. 
5. Remove the rear plate of the enclosure. Refer to Figure 1 and do the following:
a.
Remove the spiral retaining ring from the back of the enclosure. Use a screwdriver to pry the end of the spiral retaining ring from the 
retaining ring groove.
b.
Pull on the T-handle to remove the rear plate from the housing. 
 
RECHARGING AND REASSEMBLY
 
Whenever the enclosure is disassembled for servicing, it should be recharged after reassembly and prior to installation. Recharging requires the 
use of a Pelco EH8000RKIT recharge kit (or equivalent) and applicable O-ring kit, part number EH8004ORKIT or EH8006ORKIT.
To prepare the enclosure for recharging, follow the steps below.
1. Once the enclosure has been disassembled, remove the O-ring from the rear plate and install a new O-ring in the O-ring groove in the rear 
plate.
2. When the new O-ring has been installed in the rear plate, smear a liberal amount of the O-ring lubricant provided with the kit on the 
exterior surface of the O-ring and rear plate. Replace the desiccant bag in the enclosure with a new one provided with the kit.
3. Slide the camera sled back into the body making sure the front lip of the sled is under the retaining bracket of the enclosure. When fully 
installed, the rear plate will fit firmly into the rear opening of the housing and the retaining groove will be fully visible.
4. Reinstall the spiral retaining ring in the retaining groove in the rear of the enclosure.
 
 
 for instructions.
 
CAUTION:  
 
Pressure must be released prior to opening the enclosure or personal injury may result.