Quick Programming Guide
ACK ACTION
Acknowledge action programs the alert label behavior after the alert condition has been
acknowledged. The following settings are available for ACK ACTION:
ALWAYS ON
The alert label is displayed until alert conditions are cleared.
OFF 8 HRS
The alert label is turned off for 8 hours. Label returns after 8 hours
if the alert condition persists.
OFF 24 HRS
The alert label is turned off for 24 hours. Label returns after 24
hours if the alert condition persists.
OFF 48 HRS
The alert label is turned off for 48 hours. Label returns after 48
hours if the alert condition persists.
ACTIVATE AUX
This setting activates an auxiliary when an alert condition exists. ACTIVATE AUX settings include
the following:
NO (default)
Not activated.
1
An alert condition will close AUX 1.
2
An alert condition will close AUX 2.
CURRENT READING
The Current Reading menu displays the existing status of temperature, pressure, and dew point
inside the dome system. An arrow displayed to the left of a menu item denotes that an alert
condition exists. An up arrow indicates the reading is over the threshold. A down arrow
indicates the reading is below the threshold.
The high temperature alert occurs if the temperature is above 140°F (60°C).
The low temperature alert occurs if the temperature is below -40°F (-40°C).
The high pressure alert occurs if the pressure is above 11 PSIG.
The low pressure alert occurs if the pressure is below 1 PSIG.
The dew point (high humidity) alert occurs if the difference between the temperature and
the dew point is less than or equal to 3°C.
NOTE:  The normal operating temperature inside the unit will be greater than the temperature
outside the back box due to the heat emitted by the system’s electronics.
RESET ALERT
Reset alert clears the alert condition and removes the alert label from the monitor. The system
automatically checks internal conditions 60 seconds after reset. If conditions are still unaccept-
able, the alert label reappears on the screen indicating further corrective action is required.
TEMPERATURE 0
°C
 
0
°F
DEWPOINT 0
°C
 
0
°F
PRESSURE 0.0 
PSIG
 
0.0  BAR
REFRESH
BACK
EXIT
CURRENT READING
REPEAT CONSTANT
ACK ACTION 
ALWAYS ON
ACTIVATE AUX 
NO
<CURRENT READING>
RESET ALERT
BACK
EXIT
ALERT
EXIT
SPECTRA III
LANGUAGE ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>
<CLEAR>
<PASSWORD>
BACK
EXIT
DOME SETTINGS