SELECTING SNMP SETTINGS
1. Place your mouse pointer over the Network tab.
2. Select SNMP from the drop-down menu.
3. Select the SNMP Version: None, V2c, or V3. None disables the SNMP configuration and is the default setting. 
NOTE: SNMP V2c and SNMP V3 configuration settings are independent of each other, but only one SNMP version can be active at a time.
CONFIGURING SNMP V2C
Figure 18. SNMP V2 Settings
1. Place your mouse pointer over the Network tab.
2. Select V2c as the SNMP Version.
3. Type the community name in the Community String box. The default name for the Community String is ”public.”
4. Configure the Trap Configuration settings. 
Address: Type the hostname or IP address of the recipient of the trap message.
Community String: Type the name of the community that should receive the trap message.
5. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
WARNING: The Simple Network Management Protocol (SNMP) settings are advanced controls. Consult your network administrator to 
obtain the required information to configure SNMP settings.