Refer to Table C when installing the PTZ device. It lists the serial port settings that the NET5301T-I supports.
Table C.  Serial Port Options and Defaults
CONNECTING A RELAY DEVICE
The NET5301T-I has an output for triggering an external device. It supports both momentary and continuous relay operation.
You can operate the relay interactively, during an active connection, or automatically to coincide with certain events. Typical applications include 
activating a door, gate or lock, or switching on lights or other electrical devices.
Figure 16 shows how to wire the relay with its power source to the video encoder (refer to Table B on page 19 for the specific connector pin 
assignments).
Figure 16.  Connecting a Relay Device
Setting
Options
Default
Data rate
(bits per second)
110, 300, 1200, 2400, 4800, 9600, 19200, 38400, 
57600, 115200, 230400
2400
Data bits
5, 6, 7, 8
8
Parity
None, Odd, Even
None
Stop bits
1, 2
1
WARNING: Do not exceed the maximum rating of 30 VDC, 1 A.
NORMALLY
OPEN (NO)
COMMON (C)
LOAD:
LIGHT/SIREN
POWER
MAX 30 VDC, 1 A
EXTERNAL
FUSE