Справочник Пользователя для Infocus INF7001A

Скачать
Страница из 38
Page 21
INF7001a Hardware Guide
TROUBLESHOOTING
SYMPTOM
POSSIBLE SOLUTIONS
No power
•  Verify the power cord is properly connected to the power outlet and to  
the monitor. 
•  Verify the power switch is ON and that the Power button on the remote or 
keypad has been turned on (the front LED should be white).
•  Plug another electrical device to the power outlet to verify that the outlet is 
supplying the proper voltage.
The monitor shuts down suddenly •  Check the Sleep Timer setting in the Configuration 2 OSD menu. Disable the 
Sleep Timer.
•  Verify that a source is active.
•  The monitor may have overheated. Remove any objects blocking the vents.
•  Review the Windows power settings of the monitor.
No image
•  If attempting to display an external source, see “No image from external 
source” below.
•  Verify that the monitor is turned on (the front LED should be white).
No image from external source
•  Verify that the source is correct by reviewing the Settings>Input Source menu.
•  Verify that connections between the source and the monitor have been  
made correctly.
•  Verify that the cables are in good condition.
•  Verify the correct input source is selected and that the input signal is 
compatible with the monitor. 
The colors on the monitor do not 
look right
•  Adjust the color settings in the Picture menu.
•  Reset the picture settings.
•  Verify that connections between the source and the monitor have been made 
correctly.
•  Verify that the cables are in good condition.
No touchpad activity with 
external computer
•  Verify that the USB B to USB type A cable is plugged from the laptop into the 
monitor correctly.
•  Verify that the laptop’s operating system is Windows® 7 or 8. (The monitor 
touchpad does not support any other operating systems.)
Touchpad functions are not 
functioning consistently
•  Remove all objects placed on the lip of the monitor and/or within 2” of the 
touchpad screen.
•  Disable the PiP feature. 
•  Power the device off and back on after a few seconds. Re-booting the device 
helps the touchpad to re-synchronize.
Remote is not working
•  Make sure the batteries are installed in the proper orientation and are not dead.
•  Verify the remote is turned on (the button is on the bottom of the remote).
•  Verify you are pointing the remote at the table and are within 26’ (8m) and 30 
degrees (horz/vert) of the sensor.
•  Verify that the IR Control setting in the Advanced Option OSD menu is set  
to Normal.