Full functionality description
4.3.5  Input detection
4.3.5.1  Input detection main menu
•  Sync response: Sets the response time of the sync detection mechanism on a loss of “sync-
locking”.
 
Fast: immediate response on a loss of sync locking by blanking the screen.
 
Slow: this setting allows a number of frames to be displayed on the screen without the
requirement for sync locking. This setting is especially useful when different input signals
are toggled in a fast way at one of the inputs of the display unit. Blanking of the screen is
avoided with this setting.
•  Single link 1-A: Submenu which allows verification of the input signal and adjustment of the
input detection settings for SDI input 1-A.
•  Single link 1-B: Submenu which allows verification of the input signal and adjustment of the
input detection settings for SDI input 1-B.
•  Dual link 1-AB: Submenu which allows verification of the input signal and adjustment of the
input detection settings in case of a dual link SDI input on 1-AB.